Description

A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".

Details

Severity MEDIUM
CVSS Score 6.2
CVSS Vector CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CWE CWE-347
Public Exploit โœ… No
Source NVD
Published 2025-05-23
Updated 2026-06-08
Modified 2025-12-09
Fix URL N/A

Affected Packages

Software From version Fixed in
sipass-integrated-ac5102-\(acc-g2\)-firmware โ€” โ€”
sipass-integrated-acc-ap-firmware โ€” โ€”

Vulnerability Monitoring

Stay informed about vulnerabilities in your stack

BotEraser monitors your WordPress installation and notifies you when software you use appears in our vulnerability database.

Set Up Free Alerts โ†’

No credit card required  ยท  Results in minutes

ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.