Description
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session.
Details
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Affected Packages
| Software | From version | Fixed in |
|---|---|---|
| 7kg9501-0aa01-2aa1-firmware | — | 2.50 |
| 7kg9501-0aa31-2aa1-firmware | — | 2.50 |
References
Similar Threats
- Critical CVE-2022-43545
- Critical CVE-2022-43439
- Critical CVE-2022-43546
Patch Gap Protection
Running software with known vulnerabilities?
BotEraser can help reduce exposure by blocking IPs associated with exploit activity — even before a patch is available.
Start Free →No credit card required · Results in minutes
ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.