Description
Softing edgeConnector Siemens OPC UA Server Null Pointer Dereference Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Softing edgeConnector Siemens. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OPC client certificates. The issue results from dereferencing a NULL pointer. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20508.
Details
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Affected Packages
| Software | From version | Fixed in |
|---|---|---|
| edgeaggregator | — | 3.70 |
| edgeconnector | — | 3.70 |
| secure-integration-server | — | 1.30 |
References
Similar Threats
- High CVE-2023-27334
- Critical CVE-2023-27335
- High CVE-2023-38125
- Medium CVE-2023-39482
- High CVE-2024-0860
Free Vulnerability Check
Is your WordPress site affected?
BotEraser helps you identify potentially vulnerable plugins and themes by checking your installation against known CVE records.
Scan My Site Free →No credit card required · Results in minutes
ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.