Description
The OTA firmware update mechanism in Netun Solutions HelpFlash IoT (firmware v18_178_221102_ASCII_PRO_1R5_50) uses hard-coded WiFi credentials identical across all devices and does not authenticate update servers or validate firmware signatures. An attacker with brief physical access can activate OTA mode (8-second button press), create a malicious WiFi AP using the known credentials, and serve malicious firmware via unauthenticated HTTP to achieve arbitrary code execution on this safety-critical emergency signaling device.
Details
CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Affected Packages
| Software | From version | Fixed in |
|---|---|---|
| helpflash-iot-firmware | — | — |
References
Site Security Check
Concerned your site may already be targeted?
BotEraser analyzes incoming traffic patterns and helps identify bot behavior consistent with known exploit attempts.
Check My Site Free →No credit card required · Results in minutes
ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.