🛡️ CVE-2024-36650 — a3100r-firmware

🟠 CVSS 7.5 — High ⚠️ Exploit Public CWE-120 NVD
7.5
CVSS Score
0 Low4 Medium7 High9 Critical10

Description

TOTOLINK AC1200 Wireless Dual Band Gigabit Router firmware A3100R V4.1.2cu.5247_B20211129, in the cgi function setNoticeCfg of the file /lib/cste_modules/system.so, the length of the user input string NoticeUrl is not checked. This can lead to a buffer overflow, allowing attackers to construct malicious HTTP or MQTT requests to cause a denial-of-service attack.

How this vulnerability can be exploited

This issue can be reached over the network, attack complexity is low, an attacker needs no privileges on the target. No user interaction is required. The scope is unchanged, so the impact stays within the vulnerable component. Rated impact: confidentiality none, integrity none, availability high.

Weakness class

CVE-2024-36650 is classified as CWE-120: Classic Buffer Overflow. Input is copied into a fixed-size buffer without a length check, overwriting memory past the end of it.

Affected software

CVE-2024-36650 is recorded against 1 package.

  • a3100r-firmware

Timeline and source

Published on 11 June 2024 and last revised on 17 June 2026. A public exploit is known to exist, which raises the urgency of patching considerably. Record sourced from NVD.

References

gist.github.com
gist.github.com

Details

Severity HIGH
CVSS Score 7.5
CVSS Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CWE CWE-120
Public Exploit ⚠️ Yes
Source NVD
Published 2024-06-11
Updated 2026-08-11
Modified 2026-06-17
Fix URL N/A

Affected Packages

Software From version Fixed in
a3100r-firmware

Similar Threats

Exploit Protection

Are you running a3100r-firmware?

CVE-2024-36650 carries CVSS 7.5 High rating and a public exploit already exists. BotEraser checks your installation against this and other known CVE records, and blocks IPs associated with exploit activity.

Check My Site For CVE-2024-36650 →

No credit card required  ·  Results in minutes

ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.

Browse related advisories

All advisoriesCVECVE 2024