Skip to main content

Boteraser | Website and Server Security Solutions

🛡️ CVE-2024-39874 — sinema-remote-connect-server

🟠 CVSS 7.5 — High ✅ No Known Exploit CWE-307 NVD
7.5
CVSS Score
0 Low4 Medium7 High9 Critical10

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.

How this vulnerability can be exploited

This issue can be reached over the network, attack complexity is low, an attacker needs no privileges on the target. No user interaction is required. The scope is unchanged, so the impact stays within the vulnerable component. Rated impact: confidentiality high, integrity none, availability none.

CVSS metrics in full

The score comes from this vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

  • Attack vector: Network — reachable from anywhere that can route to the service.
  • Attack complexity: Low — the attack works reliably, with no preparation.
  • Privileges required: None — an unauthenticated stranger can try it.
  • User interaction: None — nobody has to be tricked into anything.
  • Scope: Unchanged — the damage stays inside the vulnerable component.
  • Confidentiality impact: High — total loss, or loss the attacker controls.
  • Integrity impact: None.
  • Availability impact: None.

Weakness class

CVE-2024-39874 is classified as CWE-307: Improper Restriction of Excessive Authentication Attempts. Repeated login attempts are not limited, leaving credentials open to brute forcing.

Affected software

CVE-2024-39874 is recorded against 1 package.

  • sinema-remote-connect-server

Timeline and source

Published on 9 July 2024 and last revised on 17 June 2026. No public exploit is currently recorded for this entry. A vendor advisory or fix has been published. Record sourced from NVD.

References

cert-portal.siemens.com
cert-portal.siemens.com

Other advisories for this package

sinema-remote-connect-server has other advisories on record. If you are patching this one, these are worth checking on the same host:

Same weakness in other software

These advisories are the same class of weakness (CWE-307: Improper Restriction of Excessive Authentication Attempts) in other software:

Details

Severity HIGH
CVSS Score 7.5
CVSS Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CWE CWE-307
Public Exploit ✅ No
Source NVD
Published 2024-07-09
Updated 2026-08-20
Modified 2026-06-17

Affected Packages

Software From version Fixed in
sinema-remote-connect-server

Similar Threats

Site Security Check

Is sinema-remote-connect-server part of your stack?

CVE-2024-39874 is rated CVSS 7.5 High. BotEraser scans your installation against known CVE records and tells you whether this vulnerability applies to the versions you actually run.

Scan My Site Free →

No credit card required  ·  Results in minutes

ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.

Browse related advisories

All advisoriesCVECVE 2024