🛡️ CVE-2025-24322 — ac6-firmware

🟠 CVSS 8.1 — High ✅ No Known Exploit CWE-304 NVD
8.1
CVSS Score
0 Low4 Medium7 High9 Critical10

Description

An unsafe default authentication vulnerability exists in the Initial Setup Authentication functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted network request can lead to arbitrary code execution. An attacker can browse to the device to trigger this vulnerability.

How this vulnerability can be exploited

This issue can be reached over the network, attack complexity is high, an attacker needs no privileges on the target. No user interaction is required. The scope is unchanged, so the impact stays within the vulnerable component. Rated impact: confidentiality high, integrity high, availability high.

CVSS metrics in full

The score comes from this vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

  • Attack vector: Network — reachable from anywhere that can route to the service.
  • Attack complexity: High — the attacker first has to win a race, learn a secret or otherwise prepare the target.
  • Privileges required: None — an unauthenticated stranger can try it.
  • User interaction: None — nobody has to be tricked into anything.
  • Scope: Unchanged — the damage stays inside the vulnerable component.
  • Confidentiality impact: High — total loss, or loss the attacker controls.
  • Integrity impact: High — total loss, or loss the attacker controls.
  • Availability impact: High — total loss, or loss the attacker controls.

Weakness class

CVE-2025-24322 is classified as CWE-304: Missing Critical Step in Authentication. The product implements an authentication technique, but it skips a step that weakens the technique.

Affected software

CVE-2025-24322 is recorded against 1 package.

  • ac6-firmware

Timeline and source

Published on 20 August 2025 and last revised on 17 June 2026. No public exploit is currently recorded for this entry. Record sourced from NVD.

References

talosintelligence.com
www.talosintelligence.com

Other advisories for this package

ac6-firmware has other advisories on record. If you are patching this one, these are worth checking on the same host:

Same weakness in other software

These advisories are the same class of weakness (CWE-304: Missing Critical Step in Authentication) in other software:

Details

Severity HIGH
CVSS Score 8.1
CVSS Vector CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE CWE-304
Public Exploit ✅ No
Source NVD
Published 2025-08-20
Updated 2026-08-20
Modified 2026-06-17
Fix URL N/A

Affected Packages

Software From version Fixed in
ac6-firmware

Similar Threats

Site Security Check

Is ac6-firmware part of your stack?

CVE-2025-24322 is rated CVSS 8.1 High. BotEraser scans your installation against known CVE records and tells you whether this vulnerability applies to the versions you actually run.

Scan My Site Free →

No credit card required  ·  Results in minutes

ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.

Browse related advisories

All advisoriesCVECVE 2025