In the Linux kernel, the following vulnerability has been resolved: iommu/arm-smmu-v3: Don't unregister on shutdown Similar to SMMUv2, this driver calls iommu_device_unregister() from the shutdown path, which removes the IOMMU groups with no coordination whatsoever with their users - shutdown methods are optional in device drivers. This can lead to NULL pointer dereferences in those drivers' DMA API calls, or worse. Instead of calling the full arm_smmu_device_remove() from arm_smmu_device_shutdown(), let's pick only the relevant function call - arm_smmu_device_disable() - more or less the reverse of arm_smmu_device_reset() - and call just that from the shutdown path.
Distribution advisory
This page covers CVE-2022-48894 as tracked by Debian, for the package linux. The fix is available in version 6.1.7-1; earlier versions remain affected.
How this vulnerability can be exploited
This issue can be reached with local access to the system, attack complexity is low, an attacker needs low-level privileges on the target. No user interaction is required. The scope is unchanged, so the impact stays within the vulnerable component. Rated impact: confidentiality none, integrity none, availability high.
Affected software
DEBIAN-CVE-2022-48894 is recorded against 1 package.
- linux (fixed in 6.1.7-1)
Timeline and source
Published on 21 August 2024 and last revised on 4 August 2026. No public exploit is currently recorded for this entry. Record sourced from OSV.
References
CVE-2022-48894 on other distributions
Each distribution ships its own build and its own fixed version. Pick the one you run:
Details
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Affected Packages
| Software | From version | Fixed in |
|---|---|---|
| linux | — | 6.1.7-1 |
References
Similar Threats
- Unknown CGA-23jx-hhcx-m389
- Unknown CGA-2qp7-6757-fmgc
- Unknown CGA-2rj5-jc55-r267
- Unknown CGA-3m96-cwq8-6xmx
- Unknown CGA-3qj9-973w-fh9g
Vulnerability Monitoring
Track new vulnerabilities in linux
DEBIAN-CVE-2022-48894 is rated CVSS 5.5 Medium. BotEraser monitors your WordPress installation and notifies you when software you use appears in our vulnerability database.
Set Up Free Alerts →No credit card required · Results in minutes
ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.