Skip to main content

Boteraser | Website and Server Security Solutions

🛡️ OESA-2025-1982 — icu (CVE-2025-5222)

🟠 CVSS 8.0 — High ✅ No Known Exploit OSV
8.0
CVSS Score
0 Low4 Medium7 High9 Critical10

Description

icu security update

Tools and utilities for developing with icu.

Security Fix(es):

A stack buffer overflow was found in Internationl components for unicode (ICU ). While running the genrb binary, the 'subtag' struct overflowed at the SRBRoot::addTag function. This issue may lead to memory corruption and local arbitrary code execution.(CVE-2025-5222)

How this vulnerability can be exploited

This issue can be reached with local access to the system, attack complexity is high, an attacker needs no privileges on the target. A user must be tricked into taking some action. The scope is unchanged, so the impact stays within the vulnerable component. Rated impact: confidentiality high, integrity high, availability high.

CVSS metrics in full

The score comes from this vector: CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H

  • Attack vector: Local — a local account, shell or session on the host is needed.
  • Attack complexity: High — the attacker first has to win a race, learn a secret or otherwise prepare the target.
  • Privileges required: None — an unauthenticated stranger can try it.
  • User interaction: Required — someone has to click, open or visit something.
  • Scope: Unchanged — the damage stays inside the vulnerable component.
  • Confidentiality impact: High — total loss, or loss the attacker controls.
  • Integrity impact: High — total loss, or loss the attacker controls.
  • Availability impact: High — total loss, or loss the attacker controls.

Affected software

OESA-2025-1982 is recorded against 1 package.

  • icu (fixed in 74.1-4.oe2403sp1)

Timeline and source

Published on 8 August 2025 and last revised on 18 August 2026. No public exploit is currently recorded for this entry. Record sourced from OSV.

References

www.openeuler.org (Advisory)
nvd.nist.gov (Advisory)

Other advisories for this package

icu has other advisories on record. If you are patching this one, these are worth checking on the same host:

Details

Severity HIGH
CVSS Score 8.0
CVSS Vector CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
CWE N/A
Public Exploit ✅ No
Source OSV
Published 2025-08-08
Updated 2026-08-20
Modified 2026-08-18
Fix URL N/A

Affected Packages

Software From version Fixed in
icu — 74.1-4.oe2403sp1

Site Security Check

Is icu part of your stack?

OESA-2025-1982 is rated CVSS 8.0 High. BotEraser scans your installation against known CVE records and tells you whether this vulnerability applies to the versions you actually run.

Scan My Site Free →

No credit card required  ·  Results in minutes

ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.

Browse related advisories

All advisoriesopenEuleropenEuler 2025
✓