A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device.

This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. 

This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system.

How this vulnerability can be exploited

This issue can be reached over the network, attack complexity is low, an attacker needs low-level privileges on the target. No user interaction is required. The scope is changed, meaning a successful attack can affect components beyond the vulnerable one. Rated impact: confidentiality none, integrity none, availability high.

CVSS metrics in full

The score comes from this vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H

  • Attack vector: Network — reachable from anywhere that can route to the service.
  • Attack complexity: Low — the attack works reliably, with no preparation.
  • Privileges required: Low — an ordinary user account is enough.
  • User interaction: None — nobody has to be tricked into anything.
  • Scope: Changed — a successful attack reaches components beyond the vulnerable one.
  • Confidentiality impact: None.
  • Integrity impact: None.
  • Availability impact: High — total loss, or loss the attacker controls.

Weakness class

CVE-2025-20174 is classified as CWE-805: Buffer Access with Incorrect Length Value. The product uses a sequential operation to read or write a buffer, but it uses an incorrect length value that causes it to access memory that is outside of the bounds of the buffer.

Affected software

CVE-2025-20174 is recorded against 2 packages.

  • ios
  • ios-xe

Timeline and source

Published on 5 February 2025 and last revised on 17 June 2026. No public exploit is currently recorded for this entry. Record sourced from NVD.

References

sec.cloudapps.cisco.com

Other advisories for this package

ios has other advisories on record. If you are patching this one, these are worth checking on the same host:

Same weakness in other software

These advisories are the same class of weakness (CWE-805: Buffer Access with Incorrect Length Value) in other software:

Details

Severity HIGH
CVSS Score 7.7
CVSS Vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H
CWE CWE-805
Public Exploit ✅ No
Source NVD
Published 2025-02-05
Updated 2026-08-20
Modified 2026-06-17
Fix URL N/A

Affected Packages

Software From version Fixed in
ios
ios-xe

Similar Threats

Site Security Check

Is ios part of your stack?

CVE-2025-20174 is rated CVSS 7.7 High. BotEraser scans your installation against known CVE records and tells you whether this vulnerability applies to the versions you actually run.

Scan My Site Free →

No credit card required  ·  Results in minutes

ⓘ Data Notice: The information presented above has been compiled from publicly available internet sources. Boteraser aggregates this data solely for informational purposes and does not independently classify, evaluate, or endorse any findings about the vulnerabilities listed. The accuracy and completeness of this information is the sole responsibility of the original publishers. Boteraser and its operators accept no liability for any decisions made based on this data.

Browse related advisories

All advisoriesCVECVE 2025